Rated Working Pressure: 0.6 MPa
Rated Flow: 5 L/S
Voltage/power Consumption: AC220V/Monitor: 1W, Scan: 50/60 w
Communication Method: Network system
Jet Pattern: Column or mist
Jet Radius: 37 m
Selling Units | : | Piece/Pieces |
Network Spray Type Automatic Jet Fire Extinguishing Device
Performance characteristics:
● Adopt dual-band infrared and ultraviolet composite flame detection technology to detect fires early and with high accuracy;● The Automatic Fire Monitor is equipped with an automatic cylindrical/mist nozzle, which sprays atomization at close range and eliminates dead corners below, which is beneficial to protecting personal and property safety;
● Fire equipment devices, fire cannons, fire blankets, fire hoses, Smoke Detectors, Fire Extinguishers and other products support OEM customization.
Maintenance of intelligent fire water cannon
1. Inspection: Regularly check whether all components of the water monitor are operating normally, including electronic control systems, water pumps, nozzles, and pipes. If abnormalities or damage are found, repair or replace them in time.
2. Anti-corrosion: Water monitors are usually used in harsh environments and are easily affected by corrosion. Therefore, the shell and internal components of the water monitor should be checked regularly for corrosion, and if necessary, anti-corrosion treatment can be carried out.
Technical parameters:
Specifications | ZDMS0. 6/5S-RS33DT | ZDMS0. 6/ 10S-RS35DT | ZDMS0. 8/20S-RS50DT | ZDMS0. 8/30S-RS55DT |
Rated working pressure (MPa) | 0.6 | 0.6 | 0.8 | 0.8 |
Maximum working pressure (MPa) | 1.0 | 1.0 | 1.6 | 1.6 |
Rated flow (L/s) | 5 | 5 | 30 | 30 |
Maximum protection radius (m) | 33 | 33 | 55 | 55 |
Jet radius (m) | 37 | 37 | 62 | 62 |
Monitoring radius (m) | 50 | 50 | 80 | 80 |
Positioning time(s) | ≤30 | ≤30 | ≤60 | ≤60 |
Horizontal rotation angle (°) | 360 | 360 | 360 | 360 |
Minimum range of pitch angle (°) | -90~+30 | -90~+30 | -90~+30 | -90~+30 |
Connection size | DN25 | DN32 | DN80 | DN80 |
Installation method | Hoisting | Hoisting | Hoisting | Hoisting |
Voltage/power consumption | AC220V/Monitor: 1W, Scan: 50/60 w | |||
Communication method | Network system | |||
Jet pattern | Column or mist |